The static heat loss and unloaded Q_0 are the most important values for both the cryogenic and the RF systems.The BEPCⅡ SRF cavity operates in a liquid helium bath contained in a vacuum insulated,liquid nitrogen cooled radiation shielded vessel.During the horizontal test at the test station,thermodynamic method is used to measure and calculate the static loss and Q_0 value of the SRF cavity.This paper has briefly introduced the method and process to measure the static loss and Q_0 value of the SRF cavity.The results under different experimental conditions are presented as important data for acceptance test of the SRF cavity.
The BEPC RF system has been changed to superconducting cavities during the last four years.In the Summer of 2006,the high power test had been successfully carried.In November,the East RF was put into commis- sioning.The SRF system above 1.0MV voltage has been reached with the e^+/e^- collision beam over 100mA,and the beam current improved to 2.5GeV/250mA with 100kW beam power.The beam test shows the good matching of the RF parameters with measuring value and theoretic calculation.The commissioning and the high power test will be presented in this paper.