A novel method applying simple, rapid, effective and inexpensive excitation-emission matrix (EEM) fluorescence spectroscopy coupled with second-order calibration method for simultaneous determination of ethoxyquin (EQ) and tert-butylhydroquinone (TBHQ) contents in biological fluid samples was developed. After a simple data preprocessing that was to insert zeros below the first-order Rayleigh scattering, the second-order calibration method based on the alternating normalization-weighed error (ANWE) algorithm was used to deal with EEM data. Via the introduced "second-order advantage", the individual con- centrations of the analytes of interest could be obtained even in the presence of uncalibrated interferences. The experimental concentration ranges for the analytes were as follows: EQ, from 4.58 to 20.6 p.g mL-1 in plasma and from 6.87 to 20.6 gg mL-1 in urine; TBHQ, from 4.49 to 20.2 ~tg mL-1 in plasma and from 6.73 to 22.4 I.tg mL-l in urine. The recoveries from spiked bi- ological fluid samples were in the ranges of 92.8%-106.2% for EQ and 94.6%-107.2% for TBHQ. These results demonstrate that the three-dimensional EEM fluorescence with second-order calibration method is a powerful tool for obtaining both EQ and TBHQ quantitative results in plasma and urine samples, and could be applied to more complex matrices.
This work presents a novel application of second-order calibration based on self-weighted alternating trilinear decomposition(SWATLD)algorithm for analyzing the HPLC-DAD data.The proposed method makes it possible to simultaneously determine teflubenzuron,hexaflumuron,flufenoxuron,chlorfluazuron,diflubenzuron and benzoylurea in different fruit samples,i.e.pear,apple and banana,in the selected time region of chromatogram.The concentration,elution time and spectral information of these benzoylurea insecticides are selectively extracted from complex matrices even in the presence of unknown interferences.The root-mean-square error of prediction(RMSEP)and figures of merit,including sensitivity(SEN),selectivity(SEL)and limit of detection(LOD)are employed to access the performance of the method.The LODs obtained for these insecticides are within the range 0.017–0.26 ppm in pears,0.039–0.33 ppm in apples,0.041–0.44 ppm in bananas,respectively.Such a chemometrics-based protocol holds great potential to be extended as a promising alternative for more practical applications in food safety and quality monitoring.
The interaction between BSA and epicatechin was studied using fluorescence quenching titrations combined with trilinear decomposition method and excitation-emission matrix(EEM)fluorescence.The resolved spectra were highly similar with the actual ones which indicated that the resolved results were reliable.The relevant parameters of the binding process were obtained by quantifying each substance in the complicated mixtures in situ.The quenching was static quenching,epicatechin had a weak interaction with BSA and the binding site was one.The total concentration and the free concentration of quenchers had different effect on the system.The results demonstrated that the method exploited in this article is a useful tool to investigate complicated interactions,avoiding complicated pretreatment and simplify experimental procedure.
A "green" and quick analytical method for complex compounds was developed for simultaneous determination of tyrosine (Tyr) and dopamine (DA) in urine samples in this paper. The three-way responsive data recorded by excitation-emission matrix fluorescence (EEM) spectrometer was analyzed using second-order calibration methods based on both parallel factor analysis (PARAFAC) and self- weighted alternating trilinear decomposition (SWATLD) algorithms. The EEM spectra of the analytes were overlapped with the background in urine samples. However the second-order advantage of both PARAFAC and SWATLD methods was exploited, even in the presence of unknown interferences and the satisfactory results can be obtained. Furthermore, the linear ranges of Tyr and DA were determined to be 0.042-6.42 p.g/mL and 0.18-4.43/ug]mL, respectively, and the accuracies of both methods were validated by the analytical figures of merit (FOM).