UWB signal digitization depends, to a large extent, on the accuracy of sampling time. A highaccuracy programmable timer is therefore the key to implementing UWB signal data acquisition. A high-accuracy programmable timer based on the principle of ramp generators is described in this paper. The counting range of the timer is up to 16 bits, the timing precision is 8 ps, and the equivalent sampling rate is up to 50G Hz. No other identical product has been reported so far. This timer was successfully used in the data acquisition system for geological radar signals developed by us.
Geological radar probing technology finds wide application in engineering projects. The high-precision characteristics of geologic radar should be studied in connection with fine processing and interpretation. This article discusses such issues as (1) geologic radar noise source and (2) fine processing and interpretation of radar data. It is focused on how to achieve fine processing and interpretation.