激光光凝法诱导大鼠高眼压模型的有效性评估被引量:3
2016年
目的评估激光光凝法诱导大鼠高眼压模型的有效性。方法 532 nm激光光凝小梁网法诱导大鼠左眼高眼压(n=45,右眼为对照眼),评估激光后大鼠眼压、视网膜神经节细胞及视网膜电图的变化;采用Tono-Lab眼压计测量清醒状态下的双眼眼压,每天1次;激光后3周,采用双盲法计数双眼视网膜铺片上免疫组织化学法标记的阳性节细胞数;记录大鼠双眼基线及处死前的视网膜电图。结果激光后90.70%(39/43眼)的大鼠眼压升高,其中需要第2次激光者占74.42%(32/43眼)。激光后右眼的眼压为(16.13±1.11)mm Hg(n=39;1 k Pa=7.5 mm Hg);左眼中有28.21%眼(n=11)眼压升高(18.27±2.53)d,其余眼(n=28)眼压升高(7.93±2.40)d,两者的眼压分别为(35.59±4.57)mm Hg、(21.56±3.06)mm Hg,两者的峰值眼压分别为(63.36±4.23)mm Hg、(49.43±7.22)mm Hg;实验眼与对照眼之间的峰值眼压差为(31.13±8.64)mm Hg,累积眼压差为(182.31±140.35)mm Hg,左右眼的眼压相比差异有显著统计学意义(P=0.000)。激光后3周,两个高眼压组的节细胞数相比,差异无统计学意义(P=0.693),左眼的节细胞丢失率为67.4%±14.8%,与右眼相比差异有显著统计学意义(P=0.000)。左眼视网膜电图明适应b波、Ph NR波及暗适应b波的潜伏期与激光前相比,差异均有统计学意义(P=0.000、0.046、0.000),其振幅与激光前相比,差异也均有显著统计学意义(P=0.001、0.000、0.000),而明适应a波的潜伏期、振幅及暗适应a波的潜伏期与激光前相比,差异均无统计学意义(P=0.138、0.198、0.092)。结论激光光凝法诱导大鼠眼压升高成功率较高,但持续时间有限,峰值眼压过高,且需重复激光,高眼压引起的节细胞丢失率高,视网膜电图提示视网膜损伤主要累及双极细胞及节细胞。
刘丽芳黄楚开林洪杰张铭志
关键词:青光眼模型免疫组织化学
Reliability of Tonolab measurements in rats被引量:1
2014年
AIM: To assess the repeatability and reproducibility of Tonolab tonometer in rats with high intraocular pressure(IOP) and evaluate its ability to detect IOP changes in rats with general anaesthesia.METHODS: Left eyes of adult Fischer rats(F344) were photocoagulated by 532 nm diode laser to induce high IOP. Hypertensive eyes of 30 conscious rats were randomly chosen to measure IOP on a single occasion.Two observers independently and alternately undertook IOP measurements consecutively for three times using the same Tonolab tonometer blind to the other observer’s IOP measurements. The within subject standard deviation(Sw), coefficient of variation(CVw)(100 ×Sw/overall mean), and intraclass correlation coefficient(ICC) were calculated to evaluate intra-observer repeatability. Inter-observer difference was analysed by using 95% limits of agreement described by Bland-Altman and paired sample t- test. Also, another13 normal F344 rats were intraperitoneally administrated with ketamine/xylazine or chloral hydrate, and IOPs of both eyes were measured by a single operator once every 5min until animals came to conscious. IOPs at various time points were compared by using one-way ANOVAs.RESULTS: Mean IOP was 35.58 mm Hg(range 17.33 to65.33 mm Hg). For intraobserver repeatability, the Sw,CVw and ICC of high IOP for two observers were 5.20 mm Hg/3.41 mm Hg, 9.98% /8.08% and 0.820/0.928 respectively.The inter-observer difference was 14.76% ±19.76% of the mean IOP of two observers, with a 95% limits of agreement-23.97% to 53.50%, and the difference between mean IOP of these two observers was statistically significant(P =0.001). IOPs dropped slightly during the first 15 min post-aneathesia, with a IOP change between0.17 and 1.17 mm Hg. IOPs changed from basline of11.75 ±2.05 mm Hg(n =12) to 8.75 ±1.06 mm Hg 20 min post-anesthesia(P =0.001), and this hypotensivecondition persisted until 80 min post-anesthesia. CONCLUSION: In this sample of hypertensive rats,Tonolab measurements demonstrated high levels of intraobserver repea
Li-Fang LiuChu-Kai HuangMing-Zhi Zhang
关键词:REPEATABILITYREPRODUCIBILITYRATS
TonoLab眼压计在遗传性小鼠高眼压模型中眼压测量的可重复性被引量:1
2014年
背景 准确的眼压测量是青光眼实验研究的基础.TonoLab是一种新型的动物眼压计,其测量眼压的可重复性尚有待验证. 目的 评估新型眼压计TonoLab在遗传性高眼压模型中的准确性. 方法 采用新型眼压计TonoLab对麻醉状态下的63只7月龄遗传性高眼压DBA/2J小鼠进行眼压测量,测量时由两位技术娴熟的操作者分别、连续测量同一只眼的眼压3次,测量不分先后顺序,采用操作者盲法获取测量数据.计算测量结果的组内标准差(Sw)、组内相关系数(ICC)及组内变异系数(CVw),以评估每位操作者测量结果的可重复性,采用Bland-Altman一致性检验评估两位操作者之间测量结果的可重复性. 结果 共测量63只小鼠126只眼,其中正常眼压者105只眼,操作者1测得的平均眼压为(12.98±1.05) mmHg(1 mmHg=0.133 kPa),操作者2为(12.41±0.92) mmHg;高眼压者21只眼,操作者1和操作者2测得的平均眼压分别为(27.76±1.95) mmHg和(27.49±1.28) mmHg.正常眼压组两位操作者测量结果的Sw、ICC及CVw分别为1.34/1.11 mmHg、0.90/0.92和8.24%/7.42%;高眼压组两位操作者测量结果的Sw、ICC及CVw分别为2.21/1.49 mmHg、0.89/0.95和6.97%/4.82%.正常眼压组两位操作者测量结果之间的平均偏差为0.60 mmHg[95%可信区间(CI):-5.20 ~6.30 mmHg],高眼压组为0.30 mmHg(95% CI:-7.30~ 7.80 mmHg).结论 TonoLab眼压计在正常眼压及高眼压小鼠中单个操作者测量结果的组内可重复性高,但两位操作者测量结果之间的可重复性较低,因此单个操作者用TonoLab眼压计测得的眼压结果可靠、准确.
刘丽芳黄楚开张铭志
关键词:可重复性眼压计