It is found that in HT-7 ohmic plasma, main energy loss comes from electron heat conduction, hence quantitative data of electron heat diffusivity is a very important issue for investigation of electron heat transportation behavior in different target plasmas so as to get high performance plasma. A time-to-peak method of the heat pulse propagation originating from the sawtooth activity on the soft x-ray intensity signal has been adopted to experimentally determine electron heat diffusivity XeHP on the HT-7 tokamak. Aiming to improve the signal-to-noise (S/N) ratio of the original signal to get a stable and reasonable electron heat diffusivity XeHD value, some data processing methods, including average of tens of sawteeth, is discussed. The electron heat diffusivity XeHP is larger than XePB which is determined from the balance of background plasma power. Based on variation of the measured electron heat diffusivity XeHP, performances of different high confinement plasmas are analyzed.
It is the first time so far as we know that two arrays of multi-channel soft x-ray detectors are used to generate twodimensional (2D) images of sawtooth oscillation on the HT-7 tokamak using the Fourier-Bessel harmonic reconstruction method, and using the singular value decomposition to analyse the data from soft x-ray cameras. By these two arrays, 2D image reconstruction of soft x-ray emissivity can be obtained without assumption of plasma rigid rotation. Tomographic reconstruction of the m=1 mode structure is obtained during the precursor oscillation of the sawtooth crash. The crescent-shaped mode structure appearing on the contour map of the soft x-ray emissivity is consistent with the quasiinterchange mode. The characteristics of the m=1/n=1 mode structure observed in the soft x-ray tomography are as follows: the magnetic surface is made up of the crescent-shaped “hot core” and the circular “cold bubble”. The structure of the magnetic surface rotates in the direction of the electron diamagnetic drift and the rotation frequency is the oscillation frequency of soft x-ray signals.
In order to estimate the electron temperature soft x-ray imaging diagnostics using a double filter technique has been developed in the HT-7 tokamak. The chosen thicknesses of the Be foil are 12.5 μm and 70 μm, respectively. In this article both the main design of the diagnostic configuration and the method to estimate the electron temperature are presented. The results agree with those estimated from the soft x-ray pulse height analyzer (PHA). The main causes of systematic error have also been investigated.
Multi-channel soft x-ray (SX) detectors are applied to generate images of magnetohydrodynamic (MHD) oscillation on the HT-7 tokamak, and the data from SX cameras are analysed by using the Fourier-Bessel harmonic reconstruction method and the singular value decomposition. The image reconstruction of SX emissivity is obtained on the assumption of plasma rigid rotation, One of the important phenomena in the HT-7 discharge is the transition from the sawtooth oscillations to the MHD oscillations when the plasma density grows higher. The MHD structure observed in the SX tomography is featured as follows: the magnetic surface of MHD structure is made up of the crescent-shaped "hot core" and the circular "cold bubble". The structure of the magnetic surface is relatively stable. It rotates in the direction of the electron diamagnetic drift at a frequency being the oscillation frequency of the MHD oscillations.