The principles, methods, technologies and application effects of several electromagnetic methods for the detection of the hidden danger of water gushing at the coal face were introduced. Also, emphasis was laid on expounding the methods, principles and effects of down-hole detections by electric transmission tomography and transient electromagnetic method. The potential of point power supplied in the underground homogeneous semi-space, as well as the response to a low-resistivity abnormal body in the homogeneous semi-space, was simulated by adopting 3-D finite element method to interpret the basic theory of the electric transmission tomography. The results of actual measurement show that the mine electromagnetic method is sensitive to water-bearing low-resistivity bodies and can play a unique role in detecting the hidden danger of water gushing at the coal face.
Radiation-shielding concrete was made with ironstone aggregate. The compressive strength is affected by multi factors. The electrical conductive properties and smart performance was discovered and investigated. Experimental results show that concrete conductivity rapidly declines with increasing loading, and the conductivity is much lower than the initial value of conductive aggregate of concrete, which may be related to special characters of ironstone. This kind of concrete has widely potential applications due to its special characters and low cost.