您的位置: 专家智库 > >

国家自然科学基金(81000632)

作品数:5 被引量:4H指数:1
相关作者:马晓伟汪静梁继民杨卫东田捷更多>>
相关机构:第四军医大学西京医院西安电子科技大学中国科学院自动化研究所更多>>
发文基金:国家自然科学基金国家重点基础研究发展计划更多>>
相关领域:生物学医药卫生理学电子电信更多>>

文献类型

  • 5篇中文期刊文章

领域

  • 2篇生物学
  • 1篇金属学及工艺
  • 1篇电子电信
  • 1篇医药卫生
  • 1篇理学

主题

  • 3篇BIOLUM...
  • 3篇TOMOGR...
  • 2篇FINITE...
  • 1篇碘放射性同位...
  • 1篇多模态
  • 1篇显像
  • 1篇裸鼠
  • 1篇甲状腺
  • 1篇核素
  • 1篇核素显像
  • 1篇放射性
  • 1篇放射性核素
  • 1篇放射性核素显...
  • 1篇放射性同位素
  • 1篇OGY
  • 1篇OL
  • 1篇PHOTON...
  • 1篇QUANTI...
  • 1篇RAPID
  • 1篇AF

机构

  • 1篇西安电子科技...
  • 1篇中国科学院自...
  • 1篇第四军医大学...

作者

  • 1篇胡振华
  • 1篇屈晓超
  • 1篇田捷
  • 1篇杨卫东
  • 1篇梁继民
  • 1篇汪静
  • 1篇马晓伟

传媒

  • 2篇Chines...
  • 2篇Intern...
  • 1篇中华核医学与...

年份

  • 4篇2012
  • 1篇2011
5 条 记 录,以下是 1-5
排序方式:
Two-stage Source Reconstruction Algorithm for Bioluminescence Tomography Using Hybrid FEM
2012年
A two-stage source reconstruction algorithm for bioluminescence tomography (BLT) is developed using hybrid finite element method (FEM). The proposed algorithm takes full advantages of linear and quadratic FEMs, which can be used to localize and quantify bioluminescent source accurately. In the first stage, a large permissible region is roughly determined and then iteratively evolved to reduce matrix dimension using efficient linear FEM. In the final stage, high-convergence quadratic FEM is applied to improve reconstruction result. Both numerical simulation and physical experiment are performed to evaluate the proposed algorithm. The relevant results demonstrate that quantitative reconstruction can be well achieved in terms of computation efficiency, source position, power density, and total power when compared with previous studies.
Hou, Yan-Bin Zhao, Heng Qu, Xiao-Chao Chen, Duo-Fang Wang, Xiao-Rui Liang, Ji-Min
关键词:TWO-STAGE
基于切伦科夫效应的裸鼠甲状腺^131I多模态显像被引量:3
2012年
目的 采用切伦科夫发光断层成像(CLT)和γ显像进行裸鼠甲状腺摄取^131I的多模态成像,探索CLT与γ显像之间的相关性。方法先对4只裸鼠[体质量(21±3)g]尾静脉注射1.67×10^7Bq^131I,在注药后0.5、3、12及24h均分别行CLT和γ显像。采用基于漫射方程(DE)的切伦科夫光源重建方法重建裸鼠体内^131I的生物分布及在不同采集时间点甲状腺摄取^131I的切伦科夫光的功率。对采集的γ显像图像勾画ROI,获得γ计数的平均值,对CLT^131I的切伦科夫光的功率和γ显像获取的γ计数行直线相关分析。结果甲状腺摄取^131I的切伦科夫光的功率在0.5、3、12和24h分别为7.80×10^13、1.62×10^12、2.20×10^-12和2.68X10^12W。甲状腺摄取^131I的切伦科夫光的功率随放射性药物注射时间的延长而逐渐增加。γ显像结果表明^131I在裸鼠腹部的摄取逐渐降低,而在甲状腺的摄取越来越高,CLT与γ显像结果具有较好的相关性(r^2=0.7620,P〈0.05)。结论CLT具有临床甲状腺成像、甲状腺疾病诊断和疗效判断的潜力。
胡振华梁继民屈晓超杨卫东马晓伟汪静田捷
关键词:碘放射性同位素甲状腺放射性核素显像
Voxel classification methodology for rapid Monte Carlo simulation of light propagation in complex media
2011年
Monte Carlo (MC) method is a statistical method for simulating photon propagation in media in the optical molecular imaging field. However, obtaining an accurate result using the method is quite time-consuming, especially because the boundary of the media is complex. A voxel classification method is proposed to reduce the computation cost. All the voxels generated by dividing the media are classified into three types (outside, boundary, and inside) according to the position of the voxel. The classified information is used to determine the relative position of the photon and the intersection between photon path and media boundary in the MC method. The influencing factors and effectiveness of the proposed method are analyzed and validated by simulation experiments.
任努努赵恒朱守平屈晓超刘宏亮胡振华梁继民田捷
关键词:PHOTONS
All-optical Quantitative Framework for Bioluminescence Tomography with Non-contact Measurement
2012年
In this contribution, we present an all-optical quantitative framework for bioluminescence tomography with non-contact measurement. The framework is comprised of four indispensable steps: extraction of the geometrical structures of the subject, light flux reconstruction on arbitrary surface, calibration and quantification of the surface light flux and internal bioluminescence reconstruction. In particular, the geometrical structures are retrieved using a completely optical method and captured under identical viewing conditions with the bioluminescent images. As a result, the proposed framework avoids the utilization of computed tomography or magnetic resonance imaging to provide the geometrical structures. On the basis of experimental measurements, we evaluate the performance of the proposed all-optical quantitative framework using a mouse shaped phantom. Preliminary result reveals the potential and feasibility of the proposed framework for bioluminescence tomography.
Xue-Li ChenHeng ZhaoXiao-Chao QuDuo-Fang ChenXiao-Rui WangJi-Min Liang
关键词:ALL-OPTICAL
Improved AFEM algorithm for bioluminescence tomography based on dual-mesh alternation strategy被引量:1
2012年
Adaptive finite element method (AFEM) is broadly adopted to recover the internal source in biological tissues. In this letter, a novel dual-mesh alternation strategy (dual-mesh AFEM) is developed for bioluminescence tomography. By comprehensively considering the error estimation of the finite element method solution on each mesh, two different adaptive strategies based on the error indicator of the reconstructed source and the photon flux density are used alternately in the process. Combined with the constantly adjusted permissible region in the adaptive process, the new algorithm can achieve a more accurate source location compared with the AFEM in the previous experiments.
李维赵恒屈晓超侯彦宾陈雪利陈多芳贺小伟张岐坦梁继民
关键词:BIOLUMINESCENCETOMOGRAPHY
共1页<1>
聚类工具0